ECO Series Off Grid Inverter 3600W 4200W 6200W

Features:

  • Pure sine wave solar inverter(on/of Grid)
  • Output power factor 1.0
  • WIFI&GPRS available for IOS and Android
  • Inverter can run without battery
  • One-key restoration to factory settings
  • Built-in Lithium battery automatic activation
  • Built-in 120A MPPT Solar charge: Max 6200W(for 3.6KW/4.2KW), Max 6500W(for 6.2KW)
  • High PV input voltage range(60 ~ 500VDC)
  • Built-in anti-dust kit for harsh environment
  • Smart battery charge design to optimize battery life
  • Dual output

get a quote

Please enable JavaScript in your browser to complete this form.
Category:

Specification

MODEL ECO-3600W ECO-4200W ECO-6200W
Phase 1-phase
Maximum PV Input Power 6200W 6200W 6500W
Rated Output Power 3600W 4200W 6200W
Maximum Solar Charging Current 120A
GRID-TIE OPERATION
PV INPUT(DC)
Nominal DC Voltage/Maximum Current 360/500VDC
Stat-up Voltage/Initial Feeding Voltage 60VDC/90VDC
MPPT Voltage Range 90-450VDC
Maximum Input Current 1/18A 2/22A
GRID OUTPUT(AC)
Nominal Output Voltage 220/230/240VAC
Output Voltage Range 195.5-253VDC
Nominal Output Current 15.7A 18.2A 27.0A
Power Factor >0.99
EFFICIENCY
Maximum Conversion Efficiency(DC/AC) 98%
TWO LOAD OUTPUT POWER
Full Load 3600W 4200W 6200W
Maxium MainLoad 3600W 4200W 6200W
Maxium Second Load(battery mode) 1200W 1400W 2067W
Maxium Load Cut Off Voltage 26VDC 26VDC 52VDC
Maxium Load Return Voltage 27VDC 27VDC 54VDC
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120-140VAC/180VAC
Acceptable Input Voltage Range 90-280VAC or 170-280VAC
Frequency Range 49-51HZ
Maxium AC Input Current 30A 30A 40A
PV INPUT(DC)
Nominal DC Voltage/Maximum DC Voltage 360/500VDC
MPPT Voltage Range 60-450VDC
Maximum Input Current 1/18A 1/22A
BATTERY MODE OUTPUT(AC)
Nominal Output Voltage 220/230/240VAC
Output Waveform Pure sine wave
Efficiency(DC to AC) 94%
BATTERY & CHARGER
Nominal DC Voltage 24VDC 48VDC
Maximum Solar Charging Current 120A 140A 120A
Maximum AC Charging Current 100A 100A 100A
Maximum Charging Current 120A 140A 120A
HYBRID OPERATION
PV INPUT(DC)
Nominal DC Voltage/Maximum DC Voltage 360/500VDC
Stat-up Voltage/Initial Feeding Voltage 90VDC/120VDC
MPPT Voltage Range 60-450VDC
Maximum Input Current 1/18A 1/22A
GRID OUTPUT(AC)
Nominal Output Voltage 220/230/240VAC
Output Voltage Range 195.5-253VDC
Nominal Output Current 15.7A 18.2A 27.0A
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120-140VAC/180VAC
Acceptable Input Voltage Range 90-280VAC or 170-280VAC
Maximum Input Current 30A 30A 40A
Maximum AC Charging Current 100A
GENERAL
PHYSICAL
Dimension,D*W*H(mm) 420*350*145
Carton Dimension,D*W*H(mm) 500*415*215
Net Weight(kgs) 9.2 9.6 10.2
Gross Weight(kgs) 10.2 10.9 11.2
INTERACE
Communication Port RS232/RS485/WIFI/GPRS/LITHIUM BATTERY
ENVIRONMENT
Humidity 5% to 95% Relative Humidity(Non-condensing)
Operationg Temperature -10℃-50℃
STANDARD
Compliance Safety CE